Free assistance 24/7
@ 337-781-0705
Compression test successful for test walls to pounds -
test # width x height #
E-1 5' x 10' 114,00
F-1 5' x 16' 6" 93,000
G-1 8' x 8' 52,400
H-1 5' x 16' 6" 76,000
LINTELS - 3 and 6 foot:
Compression test successful to pounds -
test # width x height #
GRAVITY LOAD:
A-4 4' x 18" 145,000
A-5 same 130,000
A-6 same 145,000
UPLIFT LOAD
A-7
same 150,000
A-8 same 170,000
A-9 same 150,000
GRAVITY LOAD:
B-4 7' x 2' 130,000
B-5 same 130,000
B-6 same 145,000
UPLIFT LOAD
B-7
same 150,000
B-8 same 130,000
B-9 same 150,000